Legionella Culture (ISO), Swab

Ordering Recommendation  Used for the detection and enumeration of both Legionella pneumophila and non-pneumophila Legionella species with routine monitoring and outbreak investigations.
Specimen Potable and Non-Potable Water
Container Type Sterile Swab and Sterile Conical Tube

 

Methodology ISO 11731:2017
Reference Range None Detected
Stability 2 days
Transport Temp Refrigerate 2° – 18° C
Instructions Swab the surface of the source to be tested using a sterile polyester-tipped swab. Do NOT use cotton-tipped swabs as they inhibit Legionella growth.To prevent drying of the swab, approximately 5 mL of source water must be added to the sterile conical tube; specimens submitted without source water will be rejected. Place the sterile swab into the conical tube and bend the swab shaft to break the swab. The entire swab should be approximately 1 inch below the top of the conical tube to avoid leakage in transit. Secure the lid, and label the conical tube with the barcoded label to identify the source.

Enter the collection time in LabCheck, providing the temperature at the time of collection, biocide, and concentration (if applicable) on the collection label; submit with the specimen.
Specimens should be collected and shipped overnight in a cooler with an ice pack, Monday-Friday only.

Days Performed Mon-Fri
Report Available 7-10 days
NY State Available  Yes
LOINC Code N/A
CPT Code N/A